Biomechanical Motion Analysis of Cervical and Thoracolumbar Spine During Ambulance Transport: A Healthy Volunteer Study

Figures

Figure 1.
Figure 1. Model of the system used for measurement (including 16 accelerometers that communicate wirelessly), and the laptop interface.
Figure 2.
Figure 2. (a) An example of a subject secured to a long spine board on the EMS stretcher with the head of the bed elevated to 10°. (b) Example of a subject secured to the stretcher with cerical collar without head blocks with the head of the bed elevated to 30°. (c) Example of a subject secured to the stretcher with cerical collar and head blocks with the head of the bed elevated to 30°.
Figure 3.
Figure 3. Bar graph with error bars of the total volumetric motion of the head relative to the torso. All subjects were fitted with a cervical collar during transport. All subjects on long spine board were also fitted with head blocks secured to the long spine board. Stretcher subjects were transported either with or without head blocks, and all transports were 8 min in duration.
Figure 4.
Figure 4. Bar graph with error bars of the total volumetric motion of the upper 10% of the thigh relative to the torso, all transports were 8 min in duration.

Table

Table 1. Changes in Vital Signs
 
MeanSDnMaximum changeMinimum change
Pain on a 1 to 10 scale. HOBE: head of bed elevation; SPB: change in systolic blood pressure (mm Hg); HR: change in heart rate (pulses per minute); SD: standard deviation.
Long spine board
  Flat
    SPB5.911.98.0270
    HR1.36.69.0140
    Pain0.21.19.030
  10° HOBE
    SPB0.613.29.0262
    HR-0.38.69.073
    Pain0.40.59.010
Stretcher mattress without head blocks
  10° HOBE
    SPB-3.29.99.0172
    HR-4.011.09.0103
    Pain0.00.09.000
  30° HOBE
    SPB-6.79.39.0251
    HR-5.010.49.082
    Pain0.00.09.000
  45° HOBE
    SPB-0.911.59.0180
    HR-5.310.39.0222
    Pain0.00.09.000
  60° HOBE
    SPB3.99.09.0170
    HR-0.74.99.0100
    Pain0.00.09.000
Stretcher mattress and head blocks
  10° HOBE
    SPB1.111.19.0140
    HR0.913.49.0272
    Pain0.40.79.020
  30° HOBE
    SPB-2.15.99.0110
    HR-6.813.19.0351
    Pain0.10.39.010
  45° HOBE
    SPB1.28.49.0162
    HR-3.89.19.0261
    Pain0.00.09.000
  60° HOBE
    SPB6.917.29.0341
    HR1.07.59.0141
    Pain0.10.39.010